NetBlasterä ZX222 User’s Guide
Fast Ethernet Adapter for PCI Mezzanine Connector (PMC)
Welcome!
Thank you for choosing the ZNYX Networks NetBlaster embedded PCI Mezzanine Card
(PMC) Fast Ethernet Adapter. Your adapter is designed to provide a lifetime of superior service
in your system with PMC slots.
NetBlaster PMC Fast Ethernet Adapter Models
·
NetBlaster PMC ZX222 provides two 100BaseFX ports with SC 62.5/125 micron
multimode fiber connectors. It is a single-wide PMC module.
Documentation and Software
Documentation and software for the NetBlaster PMC adapter is distributed electronically. You
can retrieve documentation and drivers from the ZNYX Networks web site in the driver
download section. Please contact ZNYX Networks Customer Support if you have trouble
locating the appropriate driver or installation documentation.
Installation Procedure
There are two basic steps you need to follow before you can operate your NetBlaster adapter.
1. Install the NetBlaster adapter (hardware)
2. Install the driver.
The steps outlined here help you install and troubleshoot the hardware. Driver installation
instructions are available along with the driver itself from the ZNYX Networks web site. To get
the most recent operating system specific driver, go to the ZNYX Networks website or contact
Technical Support at:
Telephone:
Fax:
(510) 249-0800 or (800) 724-0911
(510) 656-2460
Email:
Website:
ZNYX Networks NetBlaster ZX222 PMC Fast Ethernet Adapter · User’s Guide
Page 3
Hardware Installation
Below are the steps necessary to install a NetBlaster adapter into a standard, PMC compliant
system. The following are detailed instructions for the hardware installation procedure.
Installing the Hardware
This installation procedure is for installing NetBlaster PMC adapter systems with an embedded
PMC slot. Some steps in this procedure may vary depending on the specific system used. Refer
to the system’s documentation if necessary.
The figure on the following page shows the installation of an adapter in a typical system.
Observe proper Electro-Static Discharge prevention
procedures at all times. Failure to do so may result
in damage to the PCI Adapter or to the system.
!
W
0 I
CPCI PMC Carrier Card
!
Do not use excessive
force.
Zx222 PMC Adapter
1. Turn off your system.
2. Discharge any static electricity from your body by touching the metal chassis, or by using
an anti-static wrist strap. If you do not have a ground strap, maintain physical contact with
the case to maintain the same electrical potential with the system.
3. Remove the motherboard or carrier card containing at least one available single-wide
PMC slot. Select a slot to install the ZNYX Networks NetBlaster adapter. Remove the cover
from the PMC slot.
ZNYX Networks NetBlaster ZX222 PMC Fast Ethernet Adapter · User’s Guide
Page 4
4. Insert the ZNYX Networks adapter into the PMC slot. Insert the bezel of the ZNYX
Networks adapter into the PMC cutout on the front panel of the motherboard or carrier
card. Do not allow the gasket in the groove of the bracket to become misshapen or
damaged. Do not operate without the gasket properly seated.
Guide the adapter down over the alignment pin. Fully seat the adapter into the mating
connectors on the motherboard or carrier card.
5. Secure the four retention screws through the ZNYX Networks adapter standoffs and
tighten.
6. Replace the motherboard or carrier card into the system.
LAN Cable Connection
The LAN cable must be properly attached to a functioning network for the adapter to operate.
Each 100BaseFX port of the ZX222 requires a standard SC multimode fiber cable. SC connector
cables support up to 412 m on 62.5/125 micron multimode fiber.
Connecting to the Network
You can connect your adapter directly to a hub or switch with any standard SC multimode fiber
cable.
Driver Installation
This section covers driver installation for the NetBlaster adapter. At this stage the adapter should
be secure in the system and all Ethernet cables should be attached. If this is not the case, return
to the “Hardware Installation” procedure in the previous section.
Download the specific driver for your system from the ZNYX Networks web site
configuration instructions. Follow the directions on line to configure the driver.
Troubleshooting
All NetBlaster adapters support plug-and-play. If you have a plug-and-play system, your card will
configure itself automatically.
If the operating system does not discover the board, try running the DOS-based diagnostics
program.
Running DOS Diagnostics
DOS-based diagnostics are also available from the ZNYX Networks web site (www.znyx.com)
to help troubleshoot hardware problems. If you believe you have a hardware problem, and have
the capability to run DOS-based diagnostics, the steps below outline the use of the diagnostics.
PMC-to-PCI adapters are available from Catalyst Enterprises (http://www.catalyst-ent.com).
ZNYX Networks NetBlaster ZX222 PMC Fast Ethernet Adapter · User’s Guide
Page 5
Testing ZX222 Adapters in DOS
1. Run the diagnostic program that came with your adapter to see if your adapter has been
properly configured. Run DIAG222.EXE off your diskette by entering:
>DIAG222 LIST
2. You will see a list below.
DIAG222 Version x.xx for ZNYX NetBlaster ZX222 2/100 Mbps adapter
(c) Copyright 2000 ZNYX Corporation - All Rights Reserved.
PCI BIOS Information: Version=2.10, Config Mechanism=1, Last Bus=2
Bus Dev Fn Vendor Device Rev Type
Lat IL IRQ Note
========== ================= ============ ========== =====
0 0 0 8086 1250 03 Host Bridge 20 - -
0 7 0 8086 7000 01 PCI-ISA
0 7 1 8086 7010 00 IDE
00 - -
20 - -
1 5 0 1011 0019 30 Ethernet
1 6 0 1011 0019 30 Ethernet
40 A 3
40 A 10 ZX222
ZX222
3. You should see two Ethernet-type devices, and the “Note” column should indicate the
devices to be ZX222’s. Each should have an IRQ (interrupt line), bus value, and a unique
device number. If so, your card has been automatically configured. Make a note of the bus
and device numbers and go on to the software installation section.
4. To test all channels of your adapter, run DIAG222 for each bus number and device number.
For example, if you have a ZX222 and the bus number is 1 and the device numbers are 4
and 5, run:
>DIAG222 1 4
>DIAG222 1 5
5. If the DIAG222 program says:
Diagnostics successfully completed.
each time, proceed with the software installation.
System-Specific Configuration Requirements
The host computer program should automatically assign all system resources, such as I/O
addresses and interrupt lines (IRQ).
Basic Troubleshooting
For all operating systems, we recommend that you try the following if you are having difficulty.
1. Make sure the board is securely seated in the slot.
2. Observe the LED’s. Each port on the ZX222 has a LINK (green) LED and an ACTIVITY
(amber) LED. The green LED illuminates upon successfully establishing a link. The amber
ZNYX Networks NetBlaster ZX222 PMC Fast Ethernet Adapter · User’s Guide
Page 6
LED illuminates during activity. Note: In most cases, the driver must be properly loaded and
configured to bring up the link. The link LED is off if there is no link established.
ZX222
3. Refer to operating system specific documentation to evaluate any error messages or logs
when the driver is loaded.
Technical Support
If you need further assistance after referring to this User’s Guide, ZNYX Networks has a
professional technical support team available to answer your questions. Contact us at:
Telephone:
Fax:
Email:
(510) 249-0800 or (800) 724-0911
(510) 656-2460
Website:
You can reach us during normal business hours, Pacific Standard Time.
ZNYX Networks NetBlaster ZX222 PMC Fast Ethernet Adapter · User’s Guide
Page 7
Appendix A: Legal Notices and Certification
CLASS 1 LASER Product:
Complies with 21 CFR 1040.10 and 1040.11.
FCC Class A Notice:
NETBLASTER ZX222
Modification to this product not authorized by ZNYX Corporation could void the FCC
approval and negate your authority to operate the product.
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference in a commercial environment. This equipment generates, uses, and
can radiate radio frequency energy and, if it is not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
Canada Compliance:
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numeriqué de la classe A est conforme à la norme NMB-003 du Canada.
CE Conformity:
The ZX222 is in compliance to CE testing according to the following standards with respect to
the stated level and given criteria:
EN55022
EN50082-1
EN55022(1998)
Class A
EN61000-4-2 (1995)
EN61000-4-3 (1995)
ENV 0204 (1995)
EN61000-4-4 (1995)
EN61000-4-5 (1995)
EN61000-4-6 (1996)
4kV (Contact Discharge) and 8kV (Air Discharge)
3V/m
1kV (power Supply) and 0.5 kV (I/O Cables)
1kV (Line to Line) and 2kV (Line to Ground)
3Vrms
EN61000-4-11 (1994) 0%, 40%, 70% of UT, voltage dips +/-10% voltage variations
THIS ADAPTER CARD IS FOR USE ONLY WITH PMC BUS COMPATIBLE SYSTEMS
THAT HAVE ENCLOSED POWER SUPPLIES WITH SELV OUTPUTS AND
INSTALLATION INSTRUCTIONS DETAILING USER INSTALLATION OF CARD
CAGE ACCESSORIES.
Manufacturer Name: ZNYX Corporation
Manufacturer Address: 48501 Warm Springs Boulevard, Suite 107
Fremont, CA 94539
ZNYX Networks NetBlaster ZX222 PMC Fast Ethernet Adapter · User’s Guide
Page 8
Warranty
ZNYX Networks warrants to the original purchaser of any ZNYX Networks NetBlaster PMC
Fast Ethernet adapter product that is to be free from defects in workmanship and materials,
under normal use and service, for the lifetime of the personal computer in which it is installed
from the date of purchase from ZNYX Networks or its authorized dealer. In order for this
warranty to be valid, this hardware product must remain in its original system and be registered
with ZNYX Networks within one year of purchase. Otherwise, ZNYX Networks warrants to
the original purchaser of this hardware product that it is to be in good working order for a period
of twelve (12) months from the date of purchase from ZNYX Networks or an authorized dealer.
Should this product, in ZNYX Network's opinion, malfunction during the applicable warranty
period, ZNYX Networks will, at its expense, repair the defective product or part or, at its option,
deliver to the Customer an equivalent product or part to replace the defective item. To prevent
damage in transport, the Customer must return the product in its original packaging or, if this is
not available, other protective packaging approved in advance by ZNYX Networks. All returned
products will become the property of ZNYX Networks. At ZNYX Network's option,
replacement parts may be new or reconditioned. Any replaced product or part has a ninety (90)
day warranty or the remainder of the initial warranty period, whichever is longer.
ZNYX Networks NetBlaster ZX222 PMC Fast Ethernet Adapter · User’s Guide
Page 9
|