Wolf Appliance Company Ventilation Hood PWC542418R User Manual |
Planning Information
Pro 54" (1372) Wall Chimney Hood
M O D E L P W C 5 4 2 4 1 8 ( R )
Hand finished
craftsmanship
Classic stainless
steel finish
Welded seams and
hemmed edges
Backdraft damper
Decorative rail
(optional)
Model PWC542418
Stainless steel
baffle filters
Model PWC542418R
Rail Option
Location of
rating plate
Recessed easy-
access controls
Halogen lighting
Infinite-speed
blower control
Model PWC542418R shown with decorative rail
Wolf Pro wall chimney hoods provide the ultimate
in ventilation. With standard elements like heat sentry
and dual setting halogen lighting, Wolf elevates the
need for ventilation to an enjoyable perk.
Wolf Pro wall chimney hoods are
available in the classic stainless steel
finish. Rail option hoods (R) come with a
classic stainless steel decorative rail and
stand-offs. Optional platinum or brass
rails match dual fuel range bezels. Pro
wall chimney hoods are sold as a shell
only, internal, in-line and remote blower
options are available.
The Pro wall chimney hood installed with an optional
6" (152), 12" (305), 18" (457) or 24" (610) classic
stainless steel duct cover completes the chimney
design. With the Pro wall chimney hood you also have
the option of a decorative rail. While a classic stainless
steel rail is standard on the (R) model, platinum or
brass rails are also available to match the bezels of our
dual fuel ranges.
Pro wall chimney ventilation hoods are recommended
for use with all Wolf cooking appliances.
Dimensions in parentheses are in
millimeters unless otherwise specified.
1
6/07
Planning Information
Pro 54" (1372) Wall Chimney Hood
M O D E L P W C 5 4 2 4 1 8 ( R )
B L O W E R O P T I O N S
S P E C I F I C A T I O N S
Overall Width of Hood
Overall Height of Hood
1200 CFM Internal Blower
as of Fall 2007
804703
801317
54" (1372)
18" (457)
1100 CFM In-Line Blower
900 CFM Remote Blower
1200 CFM Remote Blower
1500 CFM Remote Blower
808332
801641
801642
804701
Overall Depth of Hood – PWC542418
PWC542418R (including rail)
24" (610)
26" (660)
Internal Blower Option
In-Line Blower Option
1200 CFM
1100 CFM
Remote Blower Options
Discharge
900, 1200 or 1500 CFM
Vertical
Refer to Pro Ventilation Recommendations
at the end of this section.
Duct Size
10" (254) Round
A C C E S S O R I E S
Electrical Supply Requirements
110/120 V AC, 60 Hz
15 amp dedicated circuit
Platinum or brass decorative rail
and stand-offs
Shipping Weight (shell only)
106 lbs (48 kg)
38" (965) high stainless steel
backsplash with warming racks
Specifications are subject to change without notice.
38" (965) high stainless steel
backsplash
6" (152), 12" (305), 18" (457) and
24" (610) duct covers
Accessories are available through your
Wolf dealer. To obtain local dealer
information, visit the Locator section of
our website, wolfappliance.com.
Dimensions in parentheses are in
millimeters unless otherwise specified.
3
Planning Information
Pro 54" (1372) Wall Chimney Hood
M O D E L P W C 5 4 2 4 1 8 ( R )
I N S T A L L A T I O N S P E C I F I C A T I O N S
LOCATION OF
6"
E
ELECTRICAL (152)
5"
(127)
18" (457)
HEIGHT
OF HOOD
54" (1372)
WIDTH OF HOOD
30" TO 36"
(762–914)
30" TO 36"
(762–914)
24" (610)
DEPTH OF HOOD
TO COUNTERTOP
TO COUNTERTOP
NOTE: Pro wall chimney hoods have a vertical discharge.
D I M E N S I O N S
Overall Width of Hood
Overall Height of Hood
54" (1372)
18" (457)
24" (610)
Overall Depth of Hood (excluding rail)
Countertop to Bottom of Hood
30" (762) to 36" (914)
Within shaded area
Location of Electrical
See Installation Instructions shipped with unit for detailed specifications.
Dimensions in parentheses are in
millimeters unless otherwise specified.
4
Planning Information
Pro 54" (1372) Wall Chimney Hood
M O D E L P W C 5 4 2 4 1 8 ( R )
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications
IMPORTANT NOTE: Install this ventilation hood
for overall dimensions and installation specifics.
only with a Wolf blower.
Wolf Pro wall chimney ventilation hoods are
recommended for use with any Wolf cooking
appliance, and should be as least as wide as
the cooking surface. It is recommended that the
hood overlap the cooking surface by 3" (76) on
either side.
Pro wall chimney hoods require a separate,
grounded 110/120 V AC, 60 Hz power supply.
The service should have its own 15 amp circuit
breaker. Placement of the electrical supply is
not critical, as long as you provide enough 120
V AC, 60 Hz power cable to make the electrical
connection. Locate electrical within the shaded
area shown in the Installation illustration.
Optional 6" (152), 12" (305), 18" (457) and
24" (610) duct covers are available as a sales
accessory to complete the chimney design.
You must follow all National Electrical Code
regulations. In addition, be aware of local codes
and ordinances when installing your service.
Installation of all Pro wall chimney hoods
should be 30" (762) to 36" (914) from the
bottom of the hood to the countertop. Follow
the dimensions shown in the Installation
illustration.
Refer to the installation instructions shipped
with each Wolf product for detailed specifica-
tions. This information can also be found on
our website, wolfappliance.com.
Wolf Pro wall chimney hoods are shipped
without a blower assembly. Internal, in-line or
remote blower assemblies are available. Blower
options also vary with the volume of air that
needs to be moved and the length of the duct
run. Refer to page 8 for Pro Ventilation CFM
Recommendations and Blower Options.
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
Planning Information
Pro 54" (1372) Wall Chimney Hood
M O D E L P W C 5 4 2 4 1 8 ( R )
D U C T I N G C O N S I D E R A T I O N S
Wolf Pro wall chimney ventilation hoods are
shipped without the blower assembly. Internal,
in-line and remote blower assemblies are
available.
Local building codes may require the use of
make-up air. Consult your local HVAC profes-
sional for specific requirements in your area.
IMPORTANT NOTE: Wolf Pro wall chimney
hoods must be vented to the outside. Use only
metal ductwork.
IMPORTANT NOTE: Install this ventilation hood
only with a Wolf blower.
Wolf Pro wall chimney hoods have a vertical
discharge location with 10" (254) round duct.
A transition with backdraft damper is included.
The hood will operate most efficiently when
ductwork does not exceed 50' (15 m) in length.
Refer to the illustration below for ducting
considerations for Pro wall chimney hoods.
Ducting for Pro wall
chimney hoods.
DUCTWORK INSTALLATION
THROUGH ROOF
ROOF CAP OR REMOTE BLOWER
10" (254) ROUND DUCT
TRANSITION
14"W x 93/4"D TO 10" ROUND
7"H (INCLUDING FLANGES)
SOFFIT OR CABINET
OR DUCT COVER
VERTICAL DISCHARGE
3
18" (457)
HEIGHT
16 /4" (425)
WALL HOOD
TOP OF WOOD
OF HOOD
MOUNTING STRIP
24" (610)
DEPTH OF HOOD
30" TO 36"
(762–914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
NOTE: VERTICAL DISCHARGE ONLY FOR PRO WALL CHIMNEY HOODS.
Dimensions in parentheses are in
millimeters unless otherwise specified.
6
Planning Information
Pro 54" (1372) Wall Chimney Hood
M O D E L P W C 5 4 2 4 1 8 ( R )
W O L F B L O W E R A S S E M B L I E S
A ventilation system must include a blower
assembly. Wolf ventilation hoods are shipped
without the blower assembly. An internal, in-line
or remote blower assembly must be selected to
accommodate the cooking appliance, CFM
requirements and homeowner preferences.
Internal, in-line and remote blower assemblies
are available as sales accessories through your
Wolf dealer.
Internal blowers are mounted inside the hood
canopy. In-line blowers are mounted in between
the hood and the exterior of the home. Remote
blowers can be mounted on the roof or in some
cases, on an exterior wall. Refer to the illustra-
tions below for dimensions of Wolf in-line and
remote blowers.
Pro ventilation recommendation charts on the
following page provide minimum CFM recom-
mendations according to the cooking appliance
and ventilation hood used and blower options
for each specific Pro wall chimney hood.
IMPORTANT NOTE: Use only a Wolf blower
with all Wolf ventilation products.
7
24 /8"
(632)
18"
12"
(457)
(305)
8"
(203)
22"
18"
(559)
(457)
In-line BLOWER-110IL
21" (533)
18" (457)
3
20 /4"
(527)
10"
10"
(254)
1
(254)
1
28 /4"
1
29 /2"
29 /2"
(718)
(749)
(749)
10" (254)
Diameter
10" (254)
Diameter
10" (254)
Diameter
1
15 /2"
(394)
3
3
14 /4"
(375)
14 /4"
(375)
1
1
1
29 /2"
29 /2"
24 /2"
(749)
(749)
(622)
3
1
14"
10 /8"
10 /8"
(356)
(264)
(257)
3
4
/4"
3
(121)
24 /4"
(629)
1
7
1
25"
22"
7
/4"
/4"
(635)
(559)
(184)
(184)
Remote BLOWER-90REM
Remote BLOWER-120REM
Remote BLOWER-150REM
Unit dimensions may vary by 1/8" (3).
Dimensions in parentheses are in
millimeters unless otherwise specified.
7
Planning Information
Pro 54" (1372) Wall Chimney Hood
M O D E L P W C 5 4 2 4 1 8 ( R )
P R O V E N T I L A T I O N C F M R E C O M M E N D AT I O N S
Pro Wall Chimney Hoods
Model
PWC362418
600
PWC422418
600
PWC482418
PWC542418
DF304 / R304 / SRT304
DF366 / R366 / SRT366 / RT366
DF364 / R364 / SRT364 / RT364
RT362
900
900
900
900
900
900
R488 / RT488
1100
1100
1100
1100
1100
1100
DF486 / R486 / SRT486 / RT486
DF484 / R484 / SRT484 / RT484
Minimum CFM requirements for Wolf ranges and rangetops. Additional CFM may be required for charbroilers, griddles
and long duct runs.
P R O V E N T I L A T I O N B L O W E R O P T I O N S
Pro Wall Chimney Hoods
Blower Description
600 CFM Internal
900 CFM Internal
1200 CFM Internal
1100 CFM In-Line
900 CFM Remote
1200 CFM Remote
1500 CFM Remote
Blower Number
CTBLOWER-60INT (801644 – 810314 as of Fall 2007)
CTBLOWER-90INT (801645 – 810315 as of Fall 2007)
IBLOWER-120INT (804703 – 810317 as of Fall 2007)
BLOWER-110IL (808332)
Wall Chimney Hood Models
PWC362418 / PWC422418
PWC362418 / PWC422418
PWC482418 / PWC542418
All Pro Wall Chimney Hoods
All Pro Wall Chimney Hoods
All Pro Wall Chimney Hoods
All Pro Wall Chimney Hoods
BLOWER-90REM (801641)
BLOWER-120REM (801642)
BLOWER-150REM (804701)
Dimensions in parentheses are in
millimeters unless otherwise specified.
8
|