30" (76.2cm) and 36" (91.4cm) Wall-Mount Range Hood
OVERALL DIMENSIONS
PRODUCT MODEL NUMBERS
8¹⁵⁄₁₆"
10¹⁵⁄₁₆"
GZ9730XS
GZ9736XS
(25.2 cm)
(27.8 cm)
A 120 Volt, 60Hz., AC only 15-amp fused, electrical supply (or circuit
breaker) is required. (A time-delay fuse or circuit breaker is
recommended.) It is recommended that a separate circuit serving only
this appliance be provided.
Set the grounded 3 prong outlet within the space covered by the
decorative flues.
7⁷⁄₈"
(20 cm)
32"
(81.3 cm) min.
46¹⁄₈"
(117.2 cm) max.
19¹⁄₁₆"
(48.4 cm)
VENTING REQUIREMENTS
Roof Venting
Wall Venting
Non-vented
(recirculating)
A
A
5¹⁄₁₆"
(12.9 cm)
B
B
19⁵⁄₈"
30" (76.2 cm)
or
(49.8 cm)
B
36" (91.4 cm)
A
CABINET OPENING DIMENSIONS
30" (76.2 cm)
or
36" (91.4 cm)
33 ⁷⁄₁₆”
(85 cm)
max.
A. Roof cap
A. Wall cap
A. Deflector
B. 6" (15.2 cm)
round vent
B. 6" (15.2 cm)
round vent
B. 6" (15.2 cm)
round vent
12" (30.5 cm) min.
14" (35.6 cm) max.
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
Vent Piece
6" (15.2 cm) Round
24" (61 cm) min.
45° elbow
2.5 ft
(0.8 m)
30" (76.2 cm) suggested max.
90° elbow
5.0 ft
(1.5 m)
3-1/4" x 10" (8.3 cm x 25 cm) vent system
3-1/4" x 10”
wall
cap
6 ft. (1.8 m)
(8.3 cm x 25 cm)
elbow
2 ft.
(0.6 m)
Maximum length
= 35 ft. (10.7 m)
1 — 90° elbow
8 ft. (2.4 m) straight
1 — wall cap
= 5.0 ft. (1.5 m)
= 8.0 ft. (2.4 m)
= 0.0 ft. (0 m)
Note:
Flexible vent is
Not recommended.
Length of system
=13.0 ft. (3.9 m)
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W100297700A